Gas detector beside a pair of ear muffs – carbon monoxide and noise exposure

Getting ready for WEL: Carbon monoxide, noise and hearing loss

Part of our Getting Ready for WEL series: practical steps to prepare your workplace for Australia’s new Workplace Exposure Limits.

In our last article we covered the new carbon monoxide (CO) limit that starts on 1 December 2026, and how to update your gas detectors to 20 ppm.

There’s something else about CO that most people don’t know.

Carbon monoxide can damage your hearing. When a worker breathes in CO and works in a noisy area at the same time, the damage to their hearing can be worse than from the noise alone.

How can a gas damage your hearing?

Your inner ear has thousands of tiny hair cells that pick up sound. Loud noise wears these cells out over time. Once they’re damaged, they don’t grow back, and that hearing is gone for good.

These hair cells need a steady supply of oxygen. CO reduces how much oxygen your blood can carry. So when a worker is breathing in CO, the cells in their ear are already under strain, and loud noise does more damage than it normally would.

Research has found that noise and CO together can cause more hearing loss than the two would cause separately. They make each other worse.

Safety regulators call chemicals that can harm hearing “ototoxic” (meaning harmful to the ear). CO is one of the most common ones in Australian workplaces, along with some solvents and metals such as lead.

Why the new limits don’t cover this

The new 20 ppm CO limit is there to protect workers from the main effect of CO: starving the body of oxygen. It isn’t designed around hearing.

The noise limit of 85 dB(A) over an 8-hour shift assumes noise is the only thing affecting the ear.

Neither limit allows for the two happening at the same time. A worker can be under the CO limit and under the noise limit, and still be at greater risk of losing their hearing.

Where this happens

If your workers need both earmuffs and a gas detector for the same job, this applies to you. Common examples:

  • Warehouses with LPG or diesel forklifts
  • Confined spaces and pits with petrol or diesel pumps, generators or compressors
  • Workshops where engines are run indoors
  • Construction work with petrol saws, compactors or generators in enclosed areas
  • Boiler rooms, furnaces and kilns
  • Fire fighting and emergency response

What to do about it

1. Aim for a lower noise level. Safe Work Australia’s guidance says that where workers are exposed to chemicals that harm hearing, noise should be kept to 80 dB(A) or below, not the usual 85. That’s a sensible target for anyone exposed to both CO and noise.

2. Get hearing tests done regularly. WorkSafe WA recommends yearly hearing tests for workers whose exposure to these chemicals reaches half the exposure limit or more. For CO under the new limit, that’s an average of about 10 ppm over a shift. Many sites with forklifts or engine-driven equipment will reach that.

3. Look at your gas detector readings. Your detector’s TWA reading shows each worker’s average CO exposure over the shift. Use it to work out who’s in the higher-risk group.

4. Fix it at the source. The best fix is to get rid of the CO and the noise rather than relying on earmuffs. For example, switch to electric forklifts or plant, keep engines well maintained, use exhaust extraction and ventilation, and choose quieter equipment.

5. Tell your workers. Most people have no idea that a gas can affect their hearing, and safety data sheets rarely mention it.

Further reading

Getting ready for WEL: Updating the CO TWA alarm on your Altair 4X


Information current as at November 2026. Sources: Safe Work Australia, SafeWork SA, WorkSafe WA and NIOSH research on noise and carbon monoxide. This article is general information only. Seek specific advice for your workplace.